2015年10月31日星期六

Gas water heater role and function of the solenoid valve

Usually gas water heater in accordance with the normal start procedure is: first, through the water, and then start the micro switch, the machine is powered and ignition, in 1-3 seconds after ignition, the magnet valve is energized, ventilation, combustion. If you lose a gas water heater valve, through the water at the time, namely ventilation, and if the ignition delay, the gas filled chamber when the detonation will occur. And talking about here is a vapor gas water heater solenoid valve linkage effect.

2015年10月25日星期日

Pulse ignition because no flame is detected to maintain the current signal

Pulse ignition because no flame is detected to maintain the current signal, unable to maintain normal gas water heater valve open, closed heater gas valve, cut off the supply of gas. Gas water heater can be friction armature movement is minimized, so that the starting current and voltage to a minimum, saving energy, but also can guarantee quick action for battery-powered gas water heater, and the use of water as the power of self-generation gas water heaters are suitable.

2015年10月19日星期一

Works gas water heater solenoid valve

Cold water into the food, water and gas flowing through the joint body under a certain pressure difference between the effect of the flow of water, promote Gas valve for water heater, and push the micro switch will power on and start the Pulse Controller, open the gas water heater valve, gas water heater burner ignition; after burner ignition, flame detection element flame signal is given to the pulse controller by detecting the flame, by maintaining the current the solenoid valve is open, maintain normal combustion burner.

2015年10月13日星期二

Structure gas water heater solenoid valve

Gas Valve For Water Heater, mainly composed of a base, fixed core, coil, armature, the fixing member, wherein the fixed core package on the base, a coil positioned on the fixed core, the armature is supported above the fixed iron core, the movable adapter , the fixed member is fixedly connected with the base, is located above the armature, both sides of the fixing member extending second clip, Water Heater Gas Valves characterized in that: said second jaw extends further toward the desired direction extending portion, corresponding to the armature and the second clip portions extend each set at a point, respectively, and two clips holding a minute gap extending portion and the second pivot axis of the swing and the core of the basic concentric action.

2015年10月7日星期三

The role of the valve

The role of the valve, there are two: one is cut off from acting, more choice of gate valves, gate opening and closing direction and generally fluid (gas, liquid) perpendicular to the direction adopted, such as hot air valve, cold air valve, combustion valves, gas burner valves, cold air gates, gas shut-off valve and the air shut-off valve. Another is the regulatory role, the choice of the valve plate can rotate the butterfly valve in the valve body, such as gas valve, air valve and mixed air control valve. Valve according to their different purposes and working conditions, choose a different material and structure.

2015年10月1日星期四

Burner safety inspection - check the gas tube group

Burner safety inspection - check the gas tube group, confirmed manually switching regulator is sensitive, the gas burner safety valve handle is installed. See if the barometer is working properly. precise when adjusting the pressure of the gas burner shown to be very critical. Rotating low pressure and high pressure switch confirm their work. Gas valve connections need to be cleaned and lubricated, if the connection bond or too rough on the right accessories you need to replace. If the burner is installed removable conduit should also pay attention to cleaning.