2015年8月26日星期三

Gas Burner Safety Valve for safety reasons

Gas Burner Safety Valve for safety reasons, in place for slightly corrosive gases, we strongly recommend:
1. double safety shut-off gas burner valves in the pipeline;
2. Install the valve leak detection devices;
3. Check the valve regularly irregular situation.

2015年8月20日星期四

Gas Burner Valves characteristics

Gas Burner Valves characteristics
1) energy saving, safe, reliable, easy-control, can adapt to the pressure fluctuations, self-regulation so that combustion, high thermal efficiency;
2) The burner valves is equipped with a small fire. The boiler starts, the first point of a small fire, when a small fire to normal and stable combustion, automatic control system only open the main gas valve, fuel can enter the normal combustion boiler does not produce deflagration;
3) applies to natural gas, liquefied petroleum gas, coal gas, liquefied petroleum gas and other types of mixed gas.

2015年8月14日星期五

Gas burners safety valve main functions

Gas Burner Safety Valve main functions: shock: in the case of the use of vibration, shaking exceeds a set value, which automatically cut off the supply Gas Valve, and automatically calls of alarm. Explosion-proof features: rubber hose off the gas. Leak detection function: This product can be used to test the leak metal hose or rubber hose and gas stove valves. Auto of alarm: automatic cut off gas supply after the distress, automatically of alarm. Our vast territory and large population, economic growth in the world and crown, increasingly improve people's living conditions, most people live without the device has been used a gas stove.

2015年8月8日星期六

Gas burner safety testing:


Gas burner safety testing:
1. Installation of the new furnace, before commissioning the gas should be carefully detect whether the requirements of the burner; check supply line of gas burner safety valve opening and closing is normal, if they are easy to use and future maintenance.
2. Newly installed pipeline, should be carefully checked for reliability and pipe installation tightness of all piping.
3. User alone gasification station, to ensure that the amount of gas, the combustion gas parameters meet the safety requirements.
4. The operator carefully read the manual of the equipment, knowledge and proficiency in the safe operation of the method.
5. Before each turn to check the gas safety valve is open, the burner does not work otherwise.

2015年8月2日星期日

Safety valve should note the following

Safety valve should note the following:
(1) there is gas in the container when liquid two-phase material safety valve should be installed in the gas phase portion.
(2) safety valve for venting flammable liquid outlet burner valves of the tank should be connected to the accident. When the discharge of the material is a high temperature fuel, its receiving container should have the appropriate protective equipment.
(3) general safety valve may be vented, the vent should be above the fire site operator 1 meter (m) or more and not toward 15 meters (m) or less, emitting sparks and high temperature equipment location. Indoor equipment, safety containers should lead roof vent and the roof above two meters (m) or more.
(4) When the inlet valve has cut off valve, cut off valve should be in a normally open state, and to be seals, to avoid mistakes.